ΤΑ80

Suction inlet: 4 inches
Outlet: 4 inches
Supply: up to 180 cubic meters per hour
Maximum head: up to 160 meters
Pump power: models of 75 and 100 ΗΡ at 2,900 revolutions per minute
Drive: right-hand or left-hand
Special materials: on order stainless steel shaft and brass fans
Waterproofing: with insulating cord
Special order mechanical gland

Methods of implementation

  1. With lubricated mount and elastic coupler on an electric motor or an internal combustion engine
  2. With lubricated ignition coil (Π45) on PTO tractors or on stationary machines (left-hand)

ΤΑ90

Suction inlet: 3 or 4 inches
Outlet: 3 inches
Supply: up to 150 cubic meters per hour
Maximum head: up to 190 meters
Pump power: 60, 75 and 100 ΗΡ at 2,900 revolutions per minute
Drive: right-hand or left-hand
Special materials: on order brass fans and stainless steel shaft
Waterproofing: with insulating cord
Special order mechanical gland

Methods of implementation

  1. With lubricated mount and elastic coupler on an electric motor or an internal combustion engine
  2. With lubricated ignition coil (Π45) on PTO tractors or on stationary machines (left-hand)

TA 3-4

Suction inlet: 4 inches
Outlet: 3 or 4 inches
Flow rate: up to 120 cubic meters per hour
Maximum head: up to 145 meters
Pump power: 40, 50 and 60 ΗΡ at 2,900 revolutions per minute
Drive: clockwise and counterclockwise
Sealing: gland packing

Implementation

  1. With lubricated mount and elastic coupler on an electric motor or an internal combustion engine
  2. With gearbox (P50) on PTO tractors or on stationary engines (counterclockwise)

31pic-Τ3-τριβάθμια-βαρέου-e

Τ3

Suction inlet: 4 inches
Outlet: 4 inches
Flow rate: up to 160 cubic meters per hour
Maximum head: up to 160 meters
Pump power: 40 and 50 ΗΡ at 1,450 revolutions per minute
On stationary machines 120 to 150 HP from 1,600 to 2,000 revolutions per minute
Drive: clockwise
Sealing: gland packing

Implementation

  1. With lubricated mount and elastic coupler on an electric motor or an internal combustion engine

Δ3

Suction inlet: 5 inches
Outlet: 4 inches
Supply: up to 300 cubic meters per hour
Maximum head: up to 150 meters
Pump power: 115 ΗΡ at 1,450 revolutions per minute
On stationary machines 175 to 240 HP from 1,400 to 2,000 revolutions per minute
Drive: right-hand
Waterproofing: with insulating cord

Methods of implementation

  1. With lubricated mount and elastic coupler on an electric motor or an internal combustion engine

PA 3-4

Suction inlet: 4 inches
Outlet: 4 inches
Flow rate: up to 120 cubic meters per hour
Maximum head: up to 195 meters
Pump power: models of 60 and 75 ΗΡ at 2,900 revolutions per minute
Drive: clockwise and counterclockwise
Sealing: gland packing

Implementation

  1. With lubricated mount and elastic coupler on an electric motor or an internal combustion engine
  2. With gearbox (P50) on PTO tractors or on stationary engines (counterclockwise)